Swarf Briquetting Press Repair Guide
Safety Precautions
- Disconnect power supply before inspection
- Lock the control panel
- Wear appropriate protective gear
Visual Inspection
- Check for loose bolts and tighten as needed
- Inspect for hydraulic fluid leaks
- Examine electrical connections for damage
- Monitor hydraulic system pressure gauge
Hydraulic System
- Tighten fittings or replace damaged hoses
- Replenish hydraulic fluid to recommended level
- Check for clogged filters if pressure abnormal
Mechanical Jams
- Inspect compression chamber for foreign objects
- Clear debris carefully
- Lubricate pistons and guide rails with recommended lubricants
Electrical Faults
- Check control panels for tripped breakers
- Interpret error codes using machine manual
- Test wiring continuity with multimeter
Post-Repair Protocol: Always perform test run at low pressure before full-load operation. Document failure cause and repair steps for future reference.